Filter Media Tester G505

The Filter Media Dynamic Filtration Performance Tester is primarily used to assess the filtration performance of filter media. This equipment is user-friendly, compact, and robu...

Introduction

The Filter Media Dynamic Filtration Performance Tester is primarily used to assess the filtration performance of filter media. This equipment is user-friendly, compact, and robust in design. It allows for quick and convenient adjustment of dust concentration values during filtration tests, with a high degree of simulation of actual conditions. After testing, the digital system of a light scattering spectrometer measures particle size and concentration online.

Application

Filter media testers are widely used in quality control and production management in industries such as pharmaceuticals, medical devices, and laboratories. They are used to evaluate the integrity, filtration efficiency, pressure drop, and other properties of filter media to ensure product hygiene and safety. Here are some specific application areas:

Pharmaceutical Industry: Filter media testers are used to evaluate filter integrity, ensuring the quality of sterile products.

Medical Devices: Filter media testers are used to test the performance of medical device filters, ensuring their effective retention of contaminants.

Laboratory: Filter media testers are used for filtration performance testing in laboratory environments, ensuring the accuracy of experimental results.

The use of filter media testers not only improves product quality but also ensures user safety. Their wide application and reliability make them indispensable equipment in modern industry.

Standards

GB/T6719-2009 : Technical requirements for bag dust collectors

ISO 11057-2011 : Filter performance test of cleanable filter media

VDI 3926-2004 : Filter performance test of cleanable filter media

ASTM D6830 : Standard Test Method for Characterizing the Pressure Drop and Filtration Performance of Cleanable Filter Media

VDI/DIN 3926:  Testing of cleanable filter media Standard test for the evaluation of cleanable filter media

GB/T 6719:  Specifications for bag house

JIS Z8909-1:  Test method of filter media for dust collection Part 1:Filter efficiency

DIN 71460-1: Road vehicles – Air filters for motor passenger compartments – Part 1: Test for particulate filtration

ISO 11 155-1: Road vehicles — Air filters for passenger compartments — Part 1: Test methods for particulate air filters

VDI 3926-II: esting of cleanable filter media – Part 2: Static filtration performance test

EN 779: Particulate air filters for general ventilation — Determination of the filtration performance

Parameters

Item Technical Parameter
Particle type Non-sticky dry powder
Continuous operation time 1–50 h
Compressed air requirement ≤ 6 bar
Dust mass flow 0.05–20 g/h, continuously adjustable, stability ≤ 5%
Aerosol outlet mass concentration 0.012–13 g/h
Power supply 100–260 VAC, 47–63 Hz
Filter test area 140 mm diameter
Filter face velocity 1–3 m/min, adjustable
Horizontal pipe flow 0–3 m³/h
Bypass pipe Extensible
Pressure sensor range 0–2000 Pa
Pressure sensor accuracy ±2%
Backflush pressure 0.2–0.6 MPa, adjustable
Backflush time 50–200 ms, adjustable
Pulse valve control Time-controlled and pressure-controlled
Suction flow controller Mass flow meter 80 LPM, accuracy 0.1 LPM
Dust dispersion air control Mass flow meter 20 LPM, accuracy 0.1 LPM
Vacuum pump 8 m³/h, 4 × 10⁻⁴ mbar, 550 W
Control software Pressure signal sampling (A/B/C/D), constant-pressure injection, aging control
Test modes Manual, semi-automatic, automatic
Data processing mode NEU data processing mode

Main features

1. The dynamic performance detection device for filter materials has the advantages of reasonable structural design, accurate test parameters, and simple and easy operation. It can complete comprehensive performance tests such as resistance and efficiency of filter material cleanliness, aging, and stability.

2. Color LCD operation interface, digital graphics processing, and XDT software can independently display the Chinese interface and edit and process the curve. It has two functions: custom and programmable, and comes with 5 standard test methods. It has a fault self-calibration function. It has an operation encryption function and can be remotely controlled.

Accessoriess

Reference Filter Media List

Flat-Sheet Filter Membrane and Weighing Filter Membrane Fixtures

Reference Pressure Drop Plate

Oil and Salt Aerosol Generators

Optional Spare Parts

FAQ

1.What is this product?

This product is a dynamic filtration performance tester for evaluating filter media efficiency, pressure drop, and dust loading behavior.

2.What is this product used for?

It is used for filtration performance testing, aging evaluation, and quality control of filter materials.

3.Why is this product important?

It provides quantitative and repeatable data on filtration performance under simulated operating conditions.

4.What industries is this product suitable for?

Pharmaceuticals, medical devices, dust collection systems, filter manufacturing, and research laboratories.

5.What types of this product are available?

The system supports flat-sheet filter media testing with configurable airflow, dust loading, and control modes.

Inquiry

    Related Products