Flatbed Ironing Tester
Category:Leather Testing Equipment
Introduction
I. Product Overview
The Flatbed Ironing Tester is a precision instrument designed to evaluate fabric performance under simulated ironing conditions. It measures heat resistance, crease recovery, and shrinkage resistance, providing critical data for textile quality control and R&D applications.
Type: Bench-top thermal testing equipment
Temperature Range: Ambient +20°C to 300°C
Pressure Control: 0.5-5 kPa adjustable (simulates iron weights)
Test Area: 300×300mm heated flatbed
Applications: Apparel, home textiles, industrial fabrics
II. Technical Specifications
Items | Parameters |
---|---|
Rainfall area | about 1300 cm2 |
Drips | 300 pieces |
Rainfall (per 100 cm2) | 100~300ml/min (adjust by valve) |
Sample size | Ф 140mm |
Test area | about 80 cm2 |
Test sample cup | 100mm |
Test sample cup mounting angle | 15 degrees |
Test sample cup rotation speed | about 6 degrees / min |
Cross wiper specifications | arm length 48mm, width 5mm |
Rotate speed of the wiper | about 20 times / min |
The friction pressure of the wiper | about 2.5N |
Test times | screen shows |
Specification of device shape | about φ80×220cm |
Weight | about 200kg |
Power supply | AC 220V 50Hz 200W |
III. Key Features
Multi-Test Modes:
Crease Recovery Test: Measures angle retention after 5min pressing
Shrinkage Test: Evaluates dimensional stability at 180°C
Heat Setting Test: Simulates industrial ironing conditions
Digital Control System:
7-inch touchscreen interface
Programmable 100-step test sequences
Real-time data logging (CSV export)
Safety Features:
Overheat protection (auto-shutdown at 310°C)
Interlock door switch
Grounding indicator
IV. Compliance Standards
ISO 3758 (Textile care labeling)
ASTM D1683 (Fabric wrinkle recovery)
AATCC 117 (Flammability resistance)
GB/T 3917.3 (Chinese textile shrinkage standard)
V. Applications
Quality Control: Batch testing of finished fabrics
R&D: Developing wrinkle-resistant treatments
Textile Education: Training on heat treatment effects
Forensic Analysis: Evaluating garment damage causes
Standard Test Procedure:
Sample Preparation: Cut 100×100mm specimens
Positioning: Center sample on heated plate
Parameter Setup: Select test mode (e.g., 200°C/3kPa/5min)
Data Acquisition: Record recovery angle/shrinkage rate
Cleaning: Autoclave decontamination cycle
Safety Precautions:
Wear heat-resistant gloves during operation
Use heat-resistant mats under equipment
Maintain 30cm clearance from flammable materials