Vacuum Cleaner Filtration Test System
Category:Filter Cartridge Filtration Tester
Introduction
Vacuum Cleaner Filters for emission characterisation of vacuum cleaners (EN 60312)
For emission tests the suction air is prepared with a dust concentration of 550 mg/m³ and passed directly into the hose of the vac.
For dust retaining tests the suction air is prepared with a dust concentration of 100 mg/m³ in the inlet channel (mixing tube) described in the standard.
Applications
Determination of particle emission of the vacuum cleaner into the exhaust air
Determination of the dust retaining capacity of the vacuum cleaner
Standard
The Vacuum Cleaner Filters is designed for tests on vacuum cleaners (vac) for household or small business use according to the standard EN 60312.
GB/T 38043-2019 Commercial Vacuum Cleaner Performance Test Methods
GB/T 4214.2-2020 Noise Measurement for Household Appliances – Vacuum Cleaner Requirements
EN 60312 Vacuum Cleaner Performance Test Standard
Commission Delegated Regulation (EU) No. 665/2013 Energy Label and Dust Re-Emission Requirements
Technical data
| Parameter title | Unit | Value |
|---|---|---|
| test flow rate | m³/h | 18 … 200 |
| power supply | – | 230 V AC; 50-60 Hz; 16 A |
| operating medium, gas/air | – | dry, particle-free compressed air |
| operating medium, gas/air – compressed air supply | bar | min. 5 (min. 5 m³/h) |
| dimensions (w × h × d) | mm | 2600 ×2500 × 850 |
| weight | kg | 350 |
Features
Manual control for service, calibration procedures and user defined tests
Automatic test procedures in accordance with standard EN 60312
Emission test with determination of the average result and determination of a confidence limit
Filtration efficiency test with determination of a confidence limit
Dust-reemission tests according to Commission Delegated Regulation (EU) No. 665 / 2013; known as ‘Energy Label for Vacuum Cleaners’
Accessories
control Software VCTWin for Vacuum Cleaner Test Rig VCT 121
FAQ
1.What is this product?
This is a vacuum cleaner filtration test system designed to evaluate particle emission, dust retention, and filtration performance of household and small commercial vacuum cleaners.
2.What is this product used for?
It is used for laboratory and production-line testing of vacuum cleaner performance, including particle emission, dust retention, filtration efficiency, and re-emission compliance.
3.Why is this product important?
It ensures vacuum cleaners meet national and international standards, supports product development, quality control, and regulatory compliance (e.g., EU energy label requirements).
4.What industries is this product suitable for?
Household appliance manufacturers, small commercial vacuum cleaner producers, third-party testing laboratories, and R&D facilities.
5.What types of tests can be performed with this system?
Particle emission tests, dust retention tests, filtration efficiency measurement, and re-emission performance evaluation under standardized and controlled conditions.