Gas Turbine Filter Test System
Category:Filter Cartridge Filtration Tester
Introduction
Test System for testing air intake filter systems for rotary machinery (ISO 29461). The test system for testing air intake filter systems for rotary machinery is based on the well-established filter test system for general air filters (ISO 16890) and extended to fulfil the specifications of ISO 29461.
It was developed with the aim of testing filters with different shapes (filter cartridges, cassette filter, filter with filter bags and plane filter media) using varying test aerosols (salt, oil) under adjustable air conditions (air humidity, temperature) within the test duct. By using the test system the following filter characteristics can be determined: differential pressure curves, dust holding capacity, gravimetric efficiency, fractional efficiency, salt removal efficiency (ISO/AWI 29461-4) and water endurance (ISO 29461-2).
Applications
Testing of gas turbine intake filter systems according to ISO 29461-2 and ISO/AWI 29461-4
Testing of general air filters (ISO 16890, EN 779, ASHRAE 52.2)
Standards
ISO 29461-1
ISO 16890-2
ISO/DIS 29461-7
ISO 12103-1
ISO 16890-3
ASHRAE 52.2
ISO 16890-4
ISO/AWI 29461-4
ISO 29461-2
Benefits
Circulation mode for control of the test parameters temperature and humidity
Injection of different aerosols (NaCl, KCl, DEHS) into an optimal flow profile
Automated feeding of water droplets and supersaturated vapour
High level of automation, mostly automated test runs with complete operator guiding
Principle
A defined volume flow rate is sucked through a HEPA intake filter, the attached test duct and the safety filter. The test system is composed of 6 sections: aerosol inlet, upstream measurement, specimen holder, downstream measurement, safety filter and flow rate measurement. The measurement sections are equipped with ports for the aerosol characterization and the determination of the pressure drop.
Technical data
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | m³/h | 800 … 11,000 |
| Test aerosol | – | DEHS, KCl, Ashrae, ISO 12103-A2 (AC fine), ISO 12103-A4 (AC coarse) |
| Test specimen dimensions | – | 610 × 610 mm (pocket and cassette filters); diameter ≤ 400 mm, length ≤ 1500 mm (filter cartridges) |
| Differential pressure of test specimen | Pa | max. 2000 |
| Compressed air supply (operating gas/air) | bar | min. 5 (17 m³/h) |
| Water supply (operating medium) | bar | min. 3 |
| Power supply | – | 3 × 400 VAC, 125 A, 50 Hz |
| Air circulation | % | 0 … 100 |
| Sensors (others) | – | Temperature, relative humidity, air pressure |
| System dimensions (W × H × D) | m | 4.6 × 1.7 × 14.0 |