
Salt Spray Testing Machine
Category:Other
Introduction
Product Introduction & Applications
The Salt Spray Testing Machine is an essential environmental testing instrument for evaluating corrosion resistance of materials and coatings. Widely used in machinery, national defense, electronics, light industry, and instrumentation, it simulates harsh saline environments to test product adaptability and durability.
This chamber can perform:
Neutral Salt Spray Tests (NSS) in accordance with GB/T 2423.17.
Acetic Acid Salt Spray Tests (CASS) to simulate aggressive corrosive environments.
Its design ensures accurate control of temperature, spray rate, and deposition uniformity, enabling reliable assessment of material performance under corrosive conditions.
Standards
GB/T 2423.17 — Basic Environmental Testing Procedures for Electric and Electronic Products: Salt Spray Test Method
Technical Parameters
| Model | Chamber Dimensions (mm) | Temperature Range (°C) | Temperature Fluctuation (°C) | Temperature Uniformity (°C) | Salt Spray Deposition Rate (ml/2000cm²·h) | Tests Capable of |
|---|---|---|---|---|---|---|
| Y-150 | 500 × 630 × 450 | 35–55 | ±0.5 | ±2 | 1–2 | Neutral, CASS |
| Y-250 | 550 × 900 × 600 | 35–55 | ±0.5 | ±2 | 1–2 | Neutral, CASS |
| Y-750 | 750 × 1100 × 600 | 35–55 | ±0.5 | ±2 | 1–2 | Neutral, CASS |
| Y-010 | 1000 × 1300 × 600 | 35–55 | ±0.5 | ±2 | 1–2 | Neutral, CASS |
| Y-016 | 1000 × 1600 × 800 | 35–55 | ±0.5 | ±2 | 1–2 | Neutral, CASS |
| Y-020 | 1000 × 2000 × 800 | 35–55 | ±0.5 | ±2 | 1–2 | Neutral, CASS |
Usage Notes
Fill the solution tank with the correct concentration of salt solution according to the test standard.
Ensure proper leveling of the chamber to maintain uniform deposition.
Regularly clean the nozzles to prevent clogging and maintain spray accuracy.
Avoid opening the chamber during operation to prevent temperature fluctuations and test interruption.
Periodically check the PID temperature controller for calibration and accuracy.
FAQ
What types of tests can this machine perform?
It can perform Neutral Salt Spray (NSS) and Acetic Acid Salt Spray (CASS) tests.
What is the temperature control accuracy?
Temperature fluctuation is ±0.5°C, and uniformity is ±2°C.
Can I monitor the test in real-time?
Yes, a transparent top cover allows continuous observation of spray status and sample condition.
How is the salt solution sprayed?
A non-clogging injection nozzle ensures continuous and uniform spray without salt crystallization.
What safety features are included?
The machine has double pressure adjustment and over-temperature protection devices for safe operation.



