Composting Biodegradation Analyzer

Applications Meets the testing requirements of GB/T 19277.1-2011. Meets the testing requirements of ISO 14855.1. Suitable for biodegradability research on bio-based materials and  products. Suitabl...

Category:Other

Factory Direct

Stable Performance

Intl. Standards

Tech Support

Fast Delivery

Global Shipping

WhatsApp Email Us
WhatsApp QR

Introduction

Applications

Meets the testing requirements of GB/T 19277.1-2011.

Meets the testing requirements of ISO 14855.1.

Suitable for biodegradability research on bio-based materials and  products.

Suitable for biodegradability testing under composting conditions.

Suitable for standard tests to measure carbon dioxide release under other  simulated aerobic composting conditions.

Working Principle

This experimental system simulates the biodegradation of bio-based materials  under aerobic composting conditions.

Under aerobic conditions, microorganisms use bio-based materials as a carbon  source, consume oxygen, and produce carbon dioxide, water, and other inorganic  substances. The concentration of the generated carbon dioxide is monitored in  real time using a high-precision infrared sensor. By integrating the measured  carbon dioxide concentration with gas flow rate and time, the total amount of  carbon dioxide released during sample biodegradation can be calculated.

The biodegradation rate is determined by the percentage of the carbon dioxide  released during sample biodegradation relative to the theoretical amount of  carbon dioxide that could be released.

Technical Parameters

Operating Conditions

Item Specification
Power Supply AC 220 V ±10%, 50 Hz, single-phase
Operating Temperature 15–30°C
Relative Humidity ≤80%
Operating Duration Suitable for long-term continuous operation
Total Power 4 kW
Overall Dimensions (L × W × H) 1500 × 900 × 900 mm
Gross Weight 180 kg

Oxygen Supply System

Item Specification
Upstream CO₂ Removal Available
Gas Supply Method Continuous aeration with a built-in gas supply  pump
Gas Pump Control Nine independently controlled channels
Flow Rate Control PLC control with automatic adjustment according to the set  value
Flow Rate Control Accuracy ±1%
Flow Rate Measurement Real-time measurement using electronic flow  meters
Flow Rate Measurement Range 0.01–500 mL/min
Number of Electronic Flow Meters 9
Flow Control and Measurement Operate independently

Temperature Control System

Item Specification
Temperature Control Method Air bath
Set Temperature Range Room temperature to 90°C
Temperature Setting Increment 0.1°C
Temperature Control Accuracy ≤±0.1°C

Reactor System

Item Specification
Number of Channels ≥9
Reactor Volume ≥2000 mL
Reactor Design Double-layer structure
Water Addition Manual
Stirring Method Manual
Reactor Bottle Material High-borosilicate hard glass
Gas Supply Method Bottom gas supply

Condensation and Dehumidification System

Item Specification
System Components Low-temperature thermostatic bath, fully automatic  condensation bottles, and dehumidification bottles
Channel Configuration Each channel is equipped with a condensation bottle and a  dehumidification bottle
Condensation Method Water-bath condensation
Condensation Temperature As low as 5°C
Drainage Method Condensate is discharged automatically at preset  intervals
Dehumidification Method Double-layer dehumidification bottle design
Connection Method Condensation bottle and dehumidification bottle connected in  series

Detection System

Item Specification
Detection Method Infrared sensor for carbon dioxide and oxygen sensor for  oxygen
Number of Sensors 1 carbon dioxide infrared sensor and 1 oxygen  sensor
Display Method Simultaneous display of concentration and cumulative  amount
Carbon Dioxide Detection Range 0–10,000 ppm
Oxygen Detection Range 0–21.0%
Carbon Dioxide Resolution 1 ppm
Oxygen Resolution 0.1%
Data Acquisition Interval 5 minutes
Sensor Dehumidification Protection Available
Gas Analyzer Compatibility Can be used in combination with a gas  analyzer

Software System

Item Specification
Software Proprietary software control system with independently owned  intellectual property rights
Data Acquisition Real-time data acquisition and curve  generation
Supported Operating Systems Professional editions of Windows 7, Windows 8, Windows 10, and  other compatible systems
Data Storage Real-time data storage during testing
Cloud Platform Remote data access and review
Continuous Operation Supports continuous operation for more than 6  months

Software displays:

Concentration and cumulative amount data

Concentration variation curves

Standard Configuration

No. Name Quantity Unit
1 Main Unit 1 Unit
2 Reactor Bottles 9 Pieces
3 CO₂ Removal Device 1 Set
4 Condensation Bottles 9 Pieces
5 Low-Temperature Thermostatic Bath 1 Set
6 Dehumidification Bottles 9 Pieces
7 Connecting Hoses 1 Set
8 Software 1 Set
9 Supplied Documentation 1 Set

Experimental Example

The following example presents the biodegradability test results of a sample  tested by an organization using an G9000 composting biodegradation analyzer by  infrared method, with reference to the test method specified in GB/T  19277.1-2011.

The test lasted 70 days. As shown in Figure 1, the biodegradation rate of  cellulose reached 81.88% within 45 days and 98.18% within 70 days. At this  stage, the increase in biodegradation across the experimental groups had largely  ceased, and the curves had leveled off.

The experimental design is presented in Table 1.

Table 1. Experimental Design

Item 1 2 3 4 5 6 7 8 9
Inoculum 300  g 300  g 300  g 300  g 300  g 300  g 300  g 300  g 300  g
Cellulose 30  g
Sample  1 30  g 30  g
Sample  2 30  g 30  g
Sample  3 30  g 30  g

Features

Fully meets the testing requirements of GB/T 19277.1.

Uses a solid culture and open oxygen supply design to simulate highly aerobic  conditions.

Provides high testing accuracy and online measurement of carbon dioxide  release.

Displays both carbon dioxide concentration and cumulative amount, with data  exportable in graphical format.

Offers a wide detection range, with an upper limit of up to 10,000 ppm.

Features a low-noise design with nine independently controlled gas supply  channels and an operating noise level below 45 dB.

Uses air-bath temperature control with a temperature adjustment accuracy of  ±0.1°C.

Features a top-opening temperature control chamber with a sliding door for  convenient operation.

Supports cloud-based testing, allowing online monitoring of data and  curves.

If you're ready to take the next step, Leave your message below and we'll reply soon. 20+ years of manufacturing & export experience, a partner you can trust.

Inquiry

    Related Products